fix(proxy): simplify planned-recreate detection to avoid isinstance on patched PrismaWrapper
Drops the isinstance(self.db, PrismaWrapper) branch (mirrors writer_db, which only narrows RoutingPrismaWrapper) and the getattr fallback so the health_check helpers do not crash when PrismaWrapper is monkeypatched to a factory in existing unit tests.
This commit is contained in:
parent
f94552881f
commit
517f54bed1
1 changed files with 3 additions and 23 deletions
|
|
@ -4749,38 +4749,18 @@ class PrismaClient:
|
|||
verbose_proxy_logger.debug("Prisma DB health watchdog observed non-DB error: %s", e)
|
||||
|
||||
def _prisma_wrappers(self) -> tuple[PrismaWrapper, ...]:
|
||||
"""Underlying writer (and reader, when read-replica routing is on)
|
||||
wrappers, so callers can inspect their planned-recreate coordination
|
||||
state regardless of routing."""
|
||||
if isinstance(self.db, RoutingPrismaWrapper):
|
||||
return (self.db.writer, self.db.reader)
|
||||
if isinstance(self.db, PrismaWrapper):
|
||||
return (self.db,)
|
||||
return ()
|
||||
return (self.db,)
|
||||
|
||||
def _engine_generations(self) -> tuple[int, ...]:
|
||||
return tuple(w._engine_generation for w in self._prisma_wrappers())
|
||||
|
||||
def _is_planned_engine_recreate_error(self, e: Exception, generations_before: tuple[int, ...]) -> bool:
|
||||
"""True iff ``e`` is a transient connection error that raced a planned
|
||||
Prisma engine recreate rather than a real DB outage.
|
||||
|
||||
Every `recreate_prisma_client` (RDS IAM token refresh, guarded
|
||||
reconnect) kills the query engine on purpose and holds the wrapper's
|
||||
`_reconnection_lock` while it spawns and connects a replacement, bumping
|
||||
`_engine_generation` on success. A `SELECT 1` probe that races that
|
||||
~0.5-1s window fails with a connection error that should not surface as
|
||||
a DB exception. We treat the error as planned when a recreate is still
|
||||
in flight (a lock is held) or when the engine generation moved while the
|
||||
probe ran. Real outages persist past the recreate window with the lock
|
||||
free and the generation unchanged, so they are still reported.
|
||||
"""
|
||||
if not PrismaDBExceptionHandler.is_database_transport_error(e):
|
||||
return False
|
||||
for wrapper in self._prisma_wrappers():
|
||||
lock = getattr(wrapper, "_reconnection_lock", None)
|
||||
if isinstance(lock, asyncio.Lock) and lock.locked():
|
||||
return True
|
||||
if any(w._reconnection_lock.locked() for w in self._prisma_wrappers()):
|
||||
return True
|
||||
return self._engine_generations() != generations_before
|
||||
|
||||